About UspNPP One Component ELISA Substrate has standard sensitivity, low background, and reliable stability within the product series, and is suitable for assays with a chromogenic reaction time of less than 30 minutes.
Art no: PNST
Package size:100mL, 1L, 5L, 10L, bulk
pH value: 9.6±0.4
Shelf life:2 years
Storage: 2-8℃
Application: ELISA、biochemical reagent
pNPP One Component ELISA Substrate
Durastab™ series pNPP substrate features low background, high stability, selectable sensitivity, and minimal lot-to-lot variation, providing an excellent signal response system suitable for the development and production of detection kits. pNPP One Component ELISA Substrate has standard sensitivity, low background, and reliable stability within the product series, and is suitable for assays with a chromogenic reaction time of less than 30 minutes.
Art no: PNST
Package size:100mL, 1L, 5L, 10L, bulk
pH value: 9.6±0.4
Shelf life:2 years
Storage: 2-8℃
Application: ELISA、biochemical reagent
Instruction:
Durastab™ pNPP One Component ELISA Substrate is readytouse and should be equilibrated to the reaction temperature before application.
ELISA Chromogenic Reaction Procedure:
1. Wash: After AP conjugate incubation, wash the plate 3 times with PBST/TBST washing buffer (containing surfactant).
2. Chromogenic reaction: Add 100 μL substrate and incubate at 20–37 °C for the appropriate time ,color is yellow;
3. Stop: Add 100 μL pNPP Stop Solution;
4. Read: Measure the absorbance at 405 nm within 30 minutes,
Kinetic measurement
1. Wash: After AP conjugate incubation, wash the plate 3 times with TBST washing buffer (containing surfactant).
2. Chromogenic reaction: Add 100 μL substrate and incubate at 20–37 °C.
Read: Measure the absorbance at 405 nm at set intervals (e.g., every 1 minute).